. Tesla, CP-mode with a 7-ms hyperbolic secant adiabatic inversion pulse (NRMSIE 30.1%), c: RF-shim with the same pulse (NRMSIE 15.7%), and d: k T -point-based 6.1-ms inversion pulse (NRMSIE ? 5%). The FA-maps of excitation pulses, all targeting an average of 6.5°, are shown alongside their corresponding FA histogram. From left to right: e:3T e s l a ,f : conventional method at 7 T, g: subject-specific RF-Shim at 7 T

T. Abraham, Evolution of Brain Imaging Instrumentation, Seminars in Nuclear Medicine, vol.41, issue.3, pp.202-219, 2011.
DOI : 10.1053/j.semnuclmed.2010.12.001

G. Adriany, P. Van-de-moortele, F. Wiesinger, S. Moeller, J. P. Strupp et al., Transmit and receive transmission line arrays for 7 Tesla parallel imaging, Magnetic Resonance in Medicine, vol.39, issue.2, pp.434-445, 2005.
DOI : 10.1002/mrm.20321

S. Akoka, F. Franconi, F. Seguin, L. Pape, and A. , Radiofrequency map of an NMR coil by imaging, Magnetic Resonance Imaging, vol.11, issue.3, pp.437-441, 1993.
DOI : 10.1016/0730-725X(93)90078-R

V. Alagappan, J. Nistler, E. Adalsteinsson, K. Setsompop, U. Fontius et al., Degenerate mode band-pass birdcage coil for accelerated parallel excitation, Magnetic Resonance in Medicine, vol.25, issue.6, pp.1148-1158, 2007.
DOI : 10.1002/mrm.21247

V. Alagappan, K. Setsompop, J. Polimeni, A. Potthast, A. Zelinski et al., Mode compression of transmit and receive arrays for parallel imaging at 7T, Proc. Intl. Soc. Mag. Reson. Med. Toronto, p.619, 2008.

L. Alon, C. M. Deniz, D. K. Sodickson, and Y. Zhu, Do constrains on |B1+| also constrain |E| and SAR in high field MR?, Proc. Intl. Soc. Mag. Reson. Med. Montreal, p.491, 2011.

N. Alperin, E. Vikingstad, B. Gomez-anson, and D. Levin, Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI, Magnetic Resonance in Medicine, vol.4, issue.5, pp.741-754, 1996.
DOI : 10.1002/mrm.1910350516

A. Amadon and N. Boulant, Simultaneous measurement of B0-and B1-maps with modified Actual Flip Angle Imaging sequence, Proc. Intl. Soc. Mag. Reson. Med. Toronto, p.1248, 2008.

A. Amadon, N. Boulant, M. A. Cloos, E. Giacomini, C. J. Wiggins et al., B1 mapping of an 8-channel TX-array over a human-head-like volume in less than 2 minutes: the XEP sequence, p.2828, 2010.

A. Amadon and M. A. Cloos, Method And Apparatus For Compensating For B1 Inhomogeneity In Magnetic Resonance Imaging By Nonselective Three-Dimensional Tailored RF Pulses, 2010.

A. Amadon, M. A. Cloos, N. Boulant, M. Hang, C. J. Wiggins et al., Validation of a very fast B1-mapping sequence for parallel transmission on a human brain at 7T, Proc. Intl. Soc. Mag. Reson. Med. Melbourne, p.p. in press, 2012.

L. Angelone, N. Makris, C. Vasios, L. Ans-wald, and B. Giorgio, Effect of Transmit Array Phase Relationship on Local Specific Absorption Rate (SAR), Proc. Intl. Soc. Mag. Reson. Med. Seattle, p.2038, 2006.

B. A. Ardekani, S. Guckemus, A. Bachman, M. J. Hoptman, M. Wojtaszek et al., Quantitative comparison of algorithms for inter-subject registration of 3D volumetric brain MRI scans, Journal of Neuroscience Methods, vol.142, issue.1, pp.67-76, 2005.
DOI : 10.1016/j.jneumeth.2004.07.014

J. Ashburner and K. J. Friston, Unified segmentation, NeuroImage, vol.26, issue.3, pp.839-851, 2005.
DOI : 10.1016/j.neuroimage.2005.02.018

J. Barna, J. Arezzo, and H. Vaughan-jr, A new multielectrode array for the simultaneous recording of field potentials and unit activity, Electroencephalography and Clinical Neurophysiology, vol.52, issue.5, pp.494-496, 1981.
DOI : 10.1016/0013-4694(81)90035-3

J. Baum, R. Tycko, and A. Pines, Broadband and adiabatic inversion of a two-level system by phase-modulated pulses, Physical Review A, vol.32, issue.6, pp.3435-3447, 1985.
DOI : 10.1103/PhysRevA.32.3435

M. S. Bazaraa, H. D. Sherali, and C. M. Shetty, Nonlinear Programming: Theory and Algorithms, 1993.
DOI : 10.1002/0471787779

M. Bernstein, I. Huston, J. Ward, and H. , Imaging artifacts at 3.0T, Journal of Magnetic Resonance Imaging, vol.19, issue.4, pp.735-746, 2006.
DOI : 10.1002/jmri.20698

M. Bernstein, K. King, and X. Zhou, Handbook of MRI Pulse Sequences, 2004.

F. Bloch, Nuclear Induction, Phys. Rev, vol.707, issue.8, pp.460-474, 1946.

P. A. Bottomley and E. R. Andrew, RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging, Physics in Medicine and Biology, vol.23, issue.4, pp.630-643, 1978.
DOI : 10.1088/0031-9155/23/4/006

N. Boulant, T1 and T2 effects during radio-frequency pulses in spoiled gradient echo sequences, Journal of Magnetic Resonance, vol.197, issue.2, pp.213-218, 2009.
DOI : 10.1016/j.jmr.2008.12.023

N. Boulant, M. Cloos, and A. Amadon, A simple and analytical way to correct for B0 inhomogeneity in the evaluation of B1 maps relying on flip angle measurements and nons-elective square pulses, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.4918, 2010.

N. Boulant, M. Cloos, A. Amadon, G. Ferrand, M. Luong et al., Flip angle and SAR maps induced by a head displacement in parallel transmission and with Cartesian feedback, Proc. Intl. Soc. Mag. Reson. Med. Stiockholm, p.1453, 2010.

N. Boulant, M. Cloos, M. Luong, G. Ferrand, C. Wiggins et al., Method for monitoring safety in parallel transmission systems based on channel-dependent average powers, Proc. Intl. Soc, 2011.

N. Boulant and D. I. Hoult, High tip angle approximation based on a modified Bloch-Riccati equation, Magnetic Resonance in Medicine, vol.82, issue.2, 2012.
DOI : 10.1002/mrm.23270

N. Boulant, L. Bihan, D. Amadon, and A. , Strongly modulating pulses for counteracting RF inhomogeneity at high fields, Magnetic Resonance in Medicine, vol.57, issue.3, pp.701-708, 2008.
DOI : 10.1002/mrm.21700

URL : https://hal.archives-ouvertes.fr/hal-00349643

N. Boulant, J. Mangin, and A. Amadon, Counteracting radio frequency inhomogeneity in the human brain at 7 Tesla using strongly modulating pulses, Magnetic Resonance in Medicine, vol.46, issue.5, pp.61-1165, 2009.
DOI : 10.1002/mrm.21955

T. Breyer, I. Wanke, S. Maderwald, F. Woermann, O. Kraff et al., Imaging of Patients with Hippocampal Sclerosis at 7 Tesla, Academic Radiology, vol.17, issue.4, 2010.
DOI : 10.1016/j.acra.2009.10.013

D. Brunner and K. Pruessmann, A matrix approach for mapping array transmit fields in under a minute, Proc. Inl. Soc. Mag. Reson. Med. Toronto, p.354, 2008.

D. O. Brunner, N. De-zanche, J. Fröhlich, J. Paska, and K. P. Pruessmann, Travelling-wave nuclear magnetic resonance, Nature, vol.49, issue.7232, pp.994-998, 2009.
DOI : 10.1038/nature07752

D. O. Brunner, J. Paska, J. Froehlich, and K. Pruessmann, SAR assesment of transmit arrays: Deterministic calculation of worst-and best-case performance, Proc. Inl. Soc. Mag. Reson. Med. p. 4803, 2008.

D. O. Brunner and K. P. Pruessmann, Optimal design of multiple-channel RF pulses under strict power and SAR constraints, Magnetic Resonance in Medicine, vol.25, issue.5, pp.1280-1291, 2010.
DOI : 10.1002/mrm.22330

J. A. Bryson and Y. Ho, Applied Optimal Control: Optimization, Estimation and Control. Taylor &F r a n c i s, 1975.

S. Buchenau, M. Haas, J. Hennig, and M. Zaitsev, On the SAR averaging nature of parallel excitation pulses and its impact on conservative worst-case analysis, Proc. Inl. Soc. Mag. Reson. Med. Stockholm, p.3884, 2010.

D. Buonomano and M. Merzenich, CORTICAL PLASTICITY: From Synapses to Maps, Annual Review of Neuroscience, vol.21, issue.1, pp.149-186, 1998.
DOI : 10.1146/annurev.neuro.21.1.149

R. F. Busse, H. Hariharan, A. Vu, and J. H. Brittain, Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinicalT2 contrast, Magnetic Resonance in Medicine, vol.33, issue.5, pp.1030-1037, 2006.
DOI : 10.1002/mrm.20863

J. Butler and R. Lowe, Beam-forming matrix simplifies design of electronically scanned antennas, Electron . Des, vol.9, issue.8, pp.170-173, 1961.

Y. Cao, E. Vikingstad, P. Huttenlocher, V. Towle, and D. Levin, Functional magnetic resonance studies of the reorganization of the human hand sensorimotor area after unilateral brain injury in the perinatal period., Proc. Nat. Acad. Sci, pp.91-9612, 1994.
DOI : 10.1073/pnas.91.20.9612

H. Carr, Free Precession Techniques in Nuclear Magnetic Resonance, 1952.

H. Carr and E. Purcell, Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments, Physical Review, vol.94, issue.3, pp.630-638, 1954.
DOI : 10.1103/PhysRev.94.630

K. C. Cheung, Implantable microscale neural interfaces, Biomedical Microdevices, vol.106, issue.6, pp.923-938, 2007.
DOI : 10.1007/s10544-006-9045-z

S. Chung, D. Kim, and E. Breton, Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout, Magnetic Resonance in Medicine, vol.145, issue.2, pp.439-446, 2010.
DOI : 10.1002/mrm.22423

M. A. Cloos and G. Bonmassar, Towards Direct B1 Based Local SAR Estimation, Proc. Intl. Soc. Mag. Reson. Med. Honolulu, p.2966, 2009.

M. A. Cloos, N. Boulant, G. Ferrand, M. Luong, C. J. Wiggins et al., T1- nonlinearity corrections for fast Transmit-Array B1+-mapping of the human brain in the small-tip-angle regime, Proc. Intl. Soc. Mag. Reson. Med. Montreal, p.4409, 2011.

M. A. Cloos, N. Boulant, M. Luong, G. Ferrand, D. L. Bihan et al., Specific absorption rate monitor for in-vivo parallel transmission at 7 Tesla, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.3871, 2010.

M. A. Cloos, N. Boulant, M. Luong, G. Ferrand, E. Giacomini et al., kT-points: Short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume, Magnetic Resonance in Medicine, vol.55, issue.1, pp.72-80, 2012.
DOI : 10.1002/mrm.22978

M. A. Cloos, N. Boulant, M. Luong, G. Ferrand, C. J. Wiggins et al., kT-points: Short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.102, 2010.
DOI : 10.1002/mrm.22978

M. A. Cloos, G. Ferrand, N. Boulant, M. Luong, C. J. Wiggins et al., Dual-channel transmit-SENSE for flip-angle homogenization in the human brain at 7 Tesla: a feasibility study, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.325, 2011.

M. A. Cloos, M. Luong, G. Ferrand, A. Amadon, L. Bihan et al., Local SAR reduction in parallel excitation based on channel-dependent Tikhonov parameters, Journal of Magnetic Resonance Imaging, vol.26, issue.5, pp.1209-1216, 2010.
DOI : 10.1002/jmri.22346

C. M. Collins and M. B. Smith, Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of ?90???? RF pulse for the head in the birdcage coil, Magnetic Resonance in Medicine, vol.40, issue.4, pp.684-691, 2001.
DOI : 10.1002/mrm.1091

C. M. Collins, W. Zhangwei, and M. B. Smith, A Conservative Method for Ensuring Safety Within Transmit Arrays, Proc. Intl. Soc. Mag. Reson. Med. Berlin, p.1092, 2007.

S. Conolly, D. Nishimura, and A. Macovski, Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem, IEEE Transactions on Medical Imaging, vol.5, issue.2, pp.106-115, 1986.
DOI : 10.1109/TMI.1986.4307754

C. H. Cunningham, J. M. Pauly, and K. S. Nayak, Saturated double-angle method for rapidB1+ mapping, Magnetic Resonance in Medicine, vol.51, issue.6, pp.1326-1333, 2006.
DOI : 10.1002/mrm.20896

R. Deichmann, C. D. Good, O. Josephs, J. Ashburner, and R. Turner, Optimization of 3D MP-RAGE sequences for structural brain imaging, NeuroImage, vol.11, issue.5, pp.112-127, 2000.
DOI : 10.1016/S1053-8119(00)91409-5

B. C. Dickerson, A. Bakkour, D. H. Salat, E. Feczko, J. Pacheco et al., The Cortical Signature of Alzheimer's Disease: Regionally Specific Cortical Thinning Relates to Symptom Severity in Very Mild to Mild AD Dementia and is Detectable in Asymptomatic Amyloid-Positive Individuals, Cerebral Cortex, vol.19, issue.3, pp.497-510, 2009.
DOI : 10.1093/cercor/bhn113

G. Duensing, D. Peterson, B. Wolverton, and J. Fitzsimmons, Transcieve Phased Array Design for Imaging at 3.0T, Proc. Intl. Soc. Mag. Reson. Med. Sydney, 1998.

G. Eichfelder and M. Gebhardt, Local specific absorption rate control for parallel transmission by virtual observation points, Magnetic Resonance in Medicine, vol.55, issue.12, pp.1468-1476, 2011.
DOI : 10.1002/mrm.22927

H. Fautz, M. Vogel, P. Gross, A. Kerr, and Y. Zhu, B1 mapping of coil arrays for parallel transmission, Proc. Int. Mag. Reson. Med. Torronto, p.1247, 2008.

D. Feinberg, J. Hoenninger, L. Crooks, L. Kaufman, J. Watts et al., Inner volume MR imaging: technical concepts and their application., Radiology, vol.156, issue.3, pp.743-747, 1985.
DOI : 10.1148/radiology.156.3.4023236

D. Feinberg, C. Mills, J. Posin, D. Ortendahl, L. Crooks et al., Multiple spin-echo magnetic resonance imaging., Radiology, vol.155, issue.2, pp.437-442, 1985.
DOI : 10.1148/radiology.155.2.3983396

G. Ferrand, M. Luong, A. Amadon, M. A. Cloos, E. Giacomini et al., Generalized double-acquisition imaging for radiofrequency inhomogeneity mitigation in high-field MRI: Experimental proof and performance analysis, Magnetic Resonance in Medicine, vol.64, issue.2, pp.175-182, 2012.
DOI : 10.1002/mrm.23006

G. Ferrand, M. Luong, M. A. Cloos, A. France, A. Amadon et al., SVD-based Hardware Concept to Drive N Transmit Elements of a Phased Array Coil with M<N Channels for Height Field MRI, Proc. Intl. Soc. Mag. Reson. Med. Montreal, p.3888, 2011.

G. Ferrand, M. Luong, and A. France, Antenne pour systeme IRM, 2010.

B. Fischl and A. Dale, Measuring the thickness of the human cerebral cortex from magnetic resonance images, Proc. Natl. Acad. Sci. USA. 97, pp.11050-11055, 2000.
DOI : 10.1073/pnas.200033797

K. Friston, J. Ashburner, C. Frith, J. Poline, J. Heather et al., Spatial registration and normalization of images, Human Brain Mapping, vol.16, issue.3, pp.165-189, 1995.
DOI : 10.1002/hbm.460030303

K. Fukunaga, S. Watanab-e, and K. Sato, Dielectric prop erties of non-toxic tissue-equivalent liquids for radiowave safety tests, IEEE Int. Conf. on Dielectric Liquids, 2005.

S. Gabriel, R. W. Lau, and C. Gabriel, The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz, Physics in Medicine and Biology, vol.41, issue.11, pp.41-2251, 1996.
DOI : 10.1088/0031-9155/41/11/002

B. A. Gagoski, R. Gumbrecht, M. Hamm, K. Setsompop, B. Keil et al., Real time RF monitoring in a 7T parallel transmit system, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.781, 2009.

I. Graesslin, Comprehensive RF safety concept for parallel transmission MR, Proc. PIERS. Boston, pp.698-700, 2008.
DOI : 10.1002/mrm.25425

I. Graesslin, S. Biederer, B. Annighoefer, H. Homann, H. Stahl et al., Real-time global and local SAR monitoring for parallel transmission systems, Proc. Intl. Soc. Mag. Reson. Med. Honolulu, p.302, 2009.

I. Graesslin, F. Schweser, B. Annighoefer, S. Biederer, U. Katscher et al., A minimum SAR RF pulse design approach for parallel Tx with local hot spot suppression and exact fidelity constraint, Proc. Intl. Soc. Mag. Reson. Med. Toronto, p.621, 2008.

D. J. Griffiths, Introduction to Quantum Mechanics, 1994.

A. Grinvald, H. Slovin, and I. Vanzetta, Non-invasive visualization of cortical columns by fMRI, Nature Neuroscience, vol.25, issue.2, pp.105-107, 2000.
DOI : 10.1038/72045

W. Grissom, C. Yip, Z. Zhang, V. A. Stenger, J. A. Fessler et al., Spatial domain method for the design of RF pulses in multicoil parallel excitation, Magnetic Resonance in Medicine, vol.38, issue.3, pp.620-629, 2006.
DOI : 10.1002/mrm.20978

W. A. Grissom and J. Pauly, Joint Design of Dual-Band Large-Tip-Angle RF and Gradient Waveforms in Parallel Excitation, Proc. Inl. Soc. Mag. Reson. Med. Stockholm, p.99, 2010.

W. A. Grissom, D. Xu, A. B. Kerr, J. A. Fessler, and D. C. Noll, Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI, IEEE Transactions on Medical Imaging, vol.28, issue.10, pp.28-1548, 2009.
DOI : 10.1109/TMI.2009.2020064

W. A. Grissom, C. Yip, S. M. Wright, J. A. Fessler, and D. C. Noll, Additive angle method for fast large-tip-angle RF pulse design in parallel excitation, Magnetic Resonance in Medicine, vol.78, issue.4, pp.779-787, 2008.
DOI : 10.1002/mrm.21510

R. Gur, P. Mozley, S. Resnick, G. Gottlieb, M. Kohn et al., Gender differences in age effect on brain atrophy measured by magnetic resonance imaging., Proc. Natl. Acad. Sci. USA, pp.88-2845, 1991.
DOI : 10.1073/pnas.88.7.2845

E. M. Haacke, R. W. Brown, M. R. Thompson, and R. Venkatesan, Magnetic Resonance Imaging: Physical Principles and Sequence Design, 1999.

A. Haase, J. Frahm, D. Matthaei, W. Hanicke, and K. Merboldt, FLASH imaging. Rapid NMR imaging using low flip-angle pulses, J. Magn. Reson, vol.67, issue.2, pp.258-266, 1986.

E. Hahn, Nuclear Induction Due to Free Larmor Precession, Physical Review, vol.77, issue.2, pp.297-298, 1950.
DOI : 10.1103/PhysRev.77.297.2

E. Hahn, Spin echoes, Phys. Rev, vol.80, issue.4, p.58, 1950.

X. Han, J. Jovicich, D. Salat, A. Van-der-kouwe, B. Quinn et al., Reliability of MRI-derived measurements of human cerebral cortical thickness: The effects of field strength, scanner upgrade and manufacturer, NeuroImage, vol.32, issue.1, pp.180-194, 2006.
DOI : 10.1016/j.neuroimage.2006.02.051

P. C. Hansen, Analysis of Discrete Ill-Posed Problems by Means of the L-Curve, SIAM Review, vol.34, issue.4, pp.561-580, 1992.
DOI : 10.1137/1034115

J. P. Hornak, J. Szumowski, and R. G. Bryant, Magnetic field mapping, Magnetic Resonance in Medicine, vol.3, issue.2, pp.158-163, 1988.
DOI : 10.1002/mrm.1910060204

D. Hoult, Sensitivity and Power Deposition in a High-Field Imaging Experiment, Journal of Magnetic Resonance Imaging, vol.1, issue.1, pp.46-67, 2000.
DOI : 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO;2-D

D. Hoult, The principle of reciprocity in signal strength calculations?A mathematical guide, Concepts in Magnetic Resonance, vol.54, issue.4, pp.173-187, 2000.
DOI : 10.1002/1099-0534(2000)12:4<173::AID-CMR1>3.0.CO;2-Q

D. Hoult and B. Bhakar, NMR signal reception: Virtual photons and coherent spontaneous emission, Concepts in Magnetic Resonance, vol.9, issue.5, pp.277-297, 1997.
DOI : 10.1002/(SICI)1099-0534(1997)9:5<277::AID-CMR1>3.0.CO;2-W

D. Hoult and P. C. Lauterbur, The sensitivity of the zeugmatographic experiment involving human samples, Journal of Magnetic Resonance (1969), vol.34, issue.2, pp.425-433, 1979.
DOI : 10.1016/0022-2364(79)90019-2

D. I. Hoult, G. Kolansky, D. Kripiakevich, and S. B. King, The NMR multi-transmit phased array: a Cartesian feedback approach, Journal of Magnetic Resonance, vol.171, issue.1, pp.64-70, 2004.
DOI : 10.1016/j.jmr.2004.07.020

T. S. Ibrahim, A. M. Abduljalil, B. A. Baertlein, R. Lee, and P. M. Robitaill, Analysis of B1 field profiles and SAR values for multi-strut transverse electromagnetic RF coils in high field MRI applications, Phys. Med. Biol, issue.10, pp.46-2545, 2001.

T. S. Ibrahim, R. Lee, A. M. Abduljalil, B. A. Baertlein, and P. Robitaille, Dielectric resonances and B1 field inhomogeneity in UHFMRI: computational analysis and experimental findings, Magnetic Resonance Imaging, vol.19, issue.2, pp.219-226, 2001.
DOI : 10.1016/S0730-725X(01)00300-9

M. Jankiewicz, H. Zeng, J. E. Moore, A. W. Anderson, M. J. Avison et al., Practical considerations for the design of sparse-spokes pulses, Journal of Magnetic Resonance, vol.203, issue.2, pp.294-304, 2010.
DOI : 10.1016/j.jmr.2010.01.012

E. Jaynes, Matrix Treatment of Nuclear Induction, Physical Review, vol.98, issue.4, pp.1099-1105, 1955.
DOI : 10.1103/PhysRev.98.1099

J. Jin, Electromagnetic Analysis and Design in Magnetic Resonance Imaging, Biomedical Engineering ), 1998.

P. Kassakian, Convex Approximation and Optimization with Applications in Magnitude Filter Design and Radiation Pattern Synthesis, 2006.

U. Katscher, P. Boernert, and C. Leussler, Transmit SENSE, Magnetic Resonance in Medicine, vol.45, issue.1, pp.144-150, 2003.
DOI : 10.1002/mrm.10353

U. Katscher, J. Lisinski, and P. Börnert, RF encoding using a multielement parallel transmit system, Magnetic Resonance in Medicine, vol.59, issue.6, pp.1463-1470, 2010.
DOI : 10.1002/mrm.22439

U. Katscher, J. Röhrs, and P. Bornert, Basic considerations on the impact of the coil array on the performance of Transmit SENSE, Magnetic Resonance Materials in Physics, Biology and Medicine, vol.18, issue.2, pp.81-88, 2005.
DOI : 10.1007/s10334-004-0096-y

U. Katscher, P. Vernickel, I. Graesslin, and P. Boernert, RF Shimming Using a Multi-Element Transmit System in Phantom and In Vivo Studies, Proc. Intl. Soc. Mag. Reson. Med. Berlin, p.1693, 2007.

U. Katscher, T. Voigt, C. Findeklee, K. Nehrke, S. Weiss et al., Estimation of local SAR using B1 mapping, Proc. Intl. Soc. Mag. Reson. Med. Toronto, p.1191, 2008.

A. B. Kerr, Y. Zhu, and J. M. Pauly, Phase Constraint Relaxation in Parallel Excitation Pulse Design, Proc. Inl. Soc. Mag. Reson. Med. Berlin, p.1694, 2007.

L. Kini, L. L. Wald, and E. Adalsteinsson, Fast E1, B1 and SAR simulation with the use of graphics processors, Proc. Intl. Soc. Mag. Reson. Med. Honolulu, p.4776, 2009.

G. R. Kirk, M. R. Haynes, S. Palasis, C. Brown, T. G. Burns et al., Regionally Specific Cortical Thinning in Children with Sickle Cell Disease, Cerebral Cortex, vol.19, issue.7, pp.1549-1556, 2009.
DOI : 10.1093/cercor/bhn193

M. Kozlov and R. Turner, Fast MRI coil analysis based on 3-D electromagnetic and RF circuit co-simulation, Journal of Magnetic Resonance, vol.200, issue.1, pp.147-152, 2009.
DOI : 10.1016/j.jmr.2009.06.005

M. Kozlov and R. Turner, Analysis of RF Transmit Performance for a 7T Dual Row Multi-Channel MRI Loop Array, Conf Proc IEEE Eng Med Biol Soc. Boston, pp.547-53, 2011.

A. Kumar, D. Welti, and R. Ernst, NMR Fourier zeugmatography, J. Magn. Reson, vol.18, issue.1, pp.69-83, 1975.

K. Kuroda, K. Oshio, A. H. Chung, K. Hynynen, and F. A. Jolesz, Temperature Mapping using the water proton chemical shift: A chemical shift selective phase mapping method, Magnetic Resonance in Medicine, vol.11, issue.5, pp.845-851, 1997.
DOI : 10.1002/mrm.1910380523

R. Lattanzi, D. K. Sodickson, A. K. Grant, and Y. Zhu, Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations, Magnetic Resonance in Medicine, vol.52, issue.2, pp.61-315, 2009.
DOI : 10.1002/mrm.21782

P. C. Lauterbur, Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance, Nature, vol.178, issue.5394, pp.190-191, 1973.
DOI : 10.1038/242190a0

P. C. Lauterbur, Magnetic resonance zeugmatography, Pure and Applied Chemistry, vol.40, issue.1-2, pp.149-157, 1974.
DOI : 10.1351/pac197440010149

D. Lee, M. Lustig, W. A. Grissom, and J. M. Pauly, Time-optimal design for multidimensional and parallel transmit variable-rate selective excitation, Magnetic Resonance in Medicine, vol.54, issue.6, pp.61-1471, 2009.
DOI : 10.1002/mrm.21950

J. Lee, M. Gebhardt, L. L. Wald, and E. Adalsteinsson, Parallel Transmit RF Design with Local SAR Constraints, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.105, 2010.

Y. Liu, K. Feng, M. P. Mcdougall, S. M. Wright, and J. Ji, Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study, Magnetic Resonance Imaging, vol.26, issue.8, pp.26-1122, 2008.
DOI : 10.1016/j.mri.2008.02.003

C. Ma, D. Xu, K. F. King, and Z. Liang, Joint design of spoke trajectories and RF pulses for parallel excitation, Magnetic Resonance in Medicine, vol.56, issue.12, pp.973-985, 2010.
DOI : 10.1002/mrm.22676

S. Maier, C. Hardy, and F. A. Jolesz, Brain and cerebrospinal fluid motion: real-time quantification with M-mode MR imaging., Radiology, vol.193, issue.2, pp.477-483, 1994.
DOI : 10.1148/radiology.193.2.7972766

N. Makris, L. M. Angelone, S. Tulloch, S. Sorg, J. Kaiser et al., MRI-based anatomical model of the human head for specific absorption rate mapping, Medical & Biological Engineering & Computing, vol.13, issue.4, pp.46-1239, 2008.
DOI : 10.1007/s11517-008-0414-z

S. J. Malik, S. Keihaninejad, A. Hammers, and J. V. Hajnal, Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses, Magnetic Resonance in Medicine, vol.42, issue.5, pp.1303-1318, 2012.
DOI : 10.1002/mrm.23118

URL : https://hal.archives-ouvertes.fr/hal-00827673

P. Mansfield, Multi-planar image formation using NMR spin echoes, Journal of Physics C: Solid State Physics, vol.10, issue.3, p.55, 1977.
DOI : 10.1088/0022-3719/10/3/004

P. Mansfield and A. Maudsley, Planar spin imaging by NMR, Journal of Physics C: Solid State Physics, vol.9, issue.15, p.409, 1976.
DOI : 10.1088/0022-3719/9/15/004

W. Mao, M. B. Smith, and C. M. Collins, Exploring the limits of RF shimming for high-field MRI of the human head, Magnetic Resonance in Medicine, vol.53, issue.4, pp.918-922, 2006.
DOI : 10.1002/mrm.21013

W. Mao, Z. Wang, and M. Smith, Calculation of SAR for transmit coil arrays, Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, vol.29, issue.2, pp.127-131, 2007.
DOI : 10.1002/cmr.b.20085

J. P. Marques, T. Kober, G. Krueger, W. Van-der-zwaag, P. Van-de-moortele et al., MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field, NeuroImage, vol.49, issue.2, pp.1271-1281, 2010.
DOI : 10.1016/j.neuroimage.2009.10.002

A. Massire, M. A. Cloos, M. Luong, A. Amadon, A. Vignaud et al., Thermal simulations in the human head for high field MRI using parallel transmission, Journal of Magnetic Resonance Imaging, vol.85, issue.6, 2012.
DOI : 10.1002/jmri.23542

G. Matson and H. Liu, Computer Simulations of 3D MPRAGE in Human Brain with Inclusion of Inadvertent Magnetization Transfer Effects, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.3008, 2010.

S. Meiboom and D. Gill, Modified Spin???Echo Method for Measuring Nuclear Relaxation Times, Review of Scientific Instruments, vol.29, issue.8, pp.688-691, 1958.
DOI : 10.1063/1.1716296

G. J. Metzger, C. Snyder, C. Akgun, T. Vaughan, K. Ugurbil et al., LocalB1+ shimming for prostate imaging with transceiver arrays at 7T based on subject-dependent transmit phase measurements, Magnetic Resonance in Medicine, vol.125, issue.2, pp.396-409, 2008.
DOI : 10.1002/mrm.21476

J. Meyer and S. Roychowdhury, Location of the central sulcus via cortical thickness of the precentral and postcentral gyri on MR, AJNR Am. J. Neuroradiol, vol.17, issue.9, pp.1699-1706, 1996.

L. Minkoff, R. Damadian, T. E. Thomas, N. Hu, M. Goldsmith et al., NMR in cancer: XVII. dewar for a 53-inch superconducting NMR magnet, Physiol. Chem. Phys, vol.9, issue.1, pp.101-104, 1977.

J. Mugler and J. Brookeman, Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE), Magnetic Resonance in Medicine, vol.8, issue.1, pp.152-157, 1990.
DOI : 10.1002/mrm.1910150117

J. P. Mugler, S. Bao, R. V. Mulkern, C. R. Guttmann, R. L. Robertson et al., Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain, Radiology, vol.216, issue.3, pp.891-899, 2000.
DOI : 10.1148/radiology.216.3.r00au46891

K. Nehrke, On the steady-state properties of actual flip angle imaging (AFI), Magnetic Resonance in Medicine, vol.210, issue.1, pp.84-92, 2009.
DOI : 10.1002/mrm.21592

K. Nehrke and P. Bornert, mapping, Magnetic Resonance in Medicine, vol.59, issue.3, pp.754-764, 2010.
DOI : 10.1002/mrm.22239

URL : https://hal.archives-ouvertes.fr/hal-00674505

J. Nelder and R. Mead, A Simplex Method for Function Minimization, The Computer Journal, vol.7, issue.4, pp.308-313, 1965.
DOI : 10.1093/comjnl/7.4.308

R. S. Nowakowski, Stable neuron numbers from cradle to grave, Proc. Natl. Acad. Sci. USA. 103 (33), pp.12219-12220, 2006.
DOI : 10.1073/pnas.0605605103

O. Ocali and E. Atalar, Ultimate intrinsic signal-to-noise ratio in MRI, Magnetic Resonance in Medicine, vol.16, issue.3, pp.462-473, 1998.
DOI : 10.1002/mrm.1910390317

H. Ohanian, What is spin?, American Journal of Physics, vol.54, issue.6, pp.500-505, 1986.
DOI : 10.1119/1.14580

M. A. Ohliger and D. K. Sodickson, An introduction to coil array design for parallel MRI, NMR in Biomedicine, vol.18, issue.3, pp.300-315, 2006.
DOI : 10.1002/nbm.1046

A. Oppelt, FISP-a new fast MRI sequence, Electromedica, vol.54, issue.1, pp.15-18, 1986.

J. Pauly, L. Roux, P. Nishimura, D. Macovski, and A. , Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging), IEEE Transactions on Medical Imaging, vol.10, issue.1, pp.53-65, 1991.
DOI : 10.1109/42.75611

J. Pauly, D. Nishimura, and A. Macovski, A linear class of large-tip-angle selective excitation pulses, Journal of Magnetic Resonance (1969), vol.82, issue.3, pp.571-587, 1989.
DOI : 10.1016/0022-2364(89)90219-9

J. M. Pauly and D. Nishimura, A k-space analysis of small-tip-angle excitation, Journal of Magnetic Resonance (1969), vol.81, issue.1, pp.43-56, 1989.
DOI : 10.1016/0022-2364(89)90265-5

R. Pohmann, An experimental comparison of B1-mapping Techniques at two field strengths, Proc. Inl. Soc. Mag. Reson. Med. Montreal, p.4410, 2011.

K. Pruessmann, M. Weiger, and M. Scheidegger, SENSE: Sensitivity encoding for fast MRI, Magnetic Resonance in Medicine, vol.30, issue.5, pp.952-962, 1999.
DOI : 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S

P. Robitaille and L. Berliner, Ultra High Field Magnetic Resonance Imaging, Biological Magnetic Resonance, vol.26, 2006.
DOI : 10.1007/978-0-387-49648-1

P. Roemer, W. Edelstein, and C. Hayes, The NMR phased array, Magnetic Resonance in Medicine, vol.67, issue.1, pp.192-225, 1990.
DOI : 10.1002/mrm.1910160203

W. D. Rooney, G. Johnson, X. Li, E. R. Cohen, S. Kim et al., Magnetic field and tissue dependencies of human brain longitudinal1H2O relaxation in vivo, Magnetic Resonance in Medicine, vol.181, issue.2, pp.308-318, 2007.
DOI : 10.1002/mrm.21122

P. Röschmann, Radiofrequency penetration and absorption in the human body: Limitations to high-field whole-body nuclear magnetic resonance imaging, Medical Physics, vol.14, issue.6, pp.922-931, 1987.
DOI : 10.1118/1.595995

S. Saekho, F. E. Boada, D. C. Noll, and V. A. Stenger, Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reducedB1 inhomogeneity at 3 T, Magnetic Resonance in Medicine, vol.49, issue.2, pp.479-484, 2005.
DOI : 10.1002/mrm.20358

S. Saekho, C. Yip, D. C. Noll, F. E. Boada, and V. A. Stenger, Fast-kz three-dimensional tailored radiofrequency pulse for reducedB1 inhomogeneity, Magnetic Resonance in Medicine, vol.52, issue.4, pp.719-724, 2006.
DOI : 10.1002/mrm.20840

A. Sbrizzi, H. Hoogduin, J. J. Lagendijk, P. Luijten, G. L. Sleijpen et al., Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems, Magnetic Resonance in Medicine, vol.17, issue.3, pp.824-834, 2012.
DOI : 10.1002/mrm.23049

J. T. Schneider, R. Kalayciyan, M. Haas, W. Ruhm, O. Doessel et al., Inner- Volume-Imaging Using Three-Dimensional Parallel Excitation, Proc. Inl. Soc. Mag. Reson. Med. Stockholm, p.103, 2010.

D. V. Schroeder, An Introduction to Thermal Physics, 1999.

I. Sersa and S. Macura, Excitation of Complicated Shapes in Three Dimensions, Journal of Magnetic Resonance, vol.135, issue.2, pp.466-477, 1998.
DOI : 10.1006/jmre.1998.1592

K. Setsompop, V. Alagappan, B. Gagoski, T. Witzel, J. Polimeni et al., 1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil, Magnetic Resonance in Medicine, vol.82, issue.6, pp.1422-1432, 2008.
DOI : 10.1002/mrm.21739

K. Setsompop, V. Alagappan, B. A. Gagoski, A. Potthast, F. Hebrank et al., mitigation at 7T via parallel spectral-spatial excitation, Magnetic Resonance in Medicine, vol.15, issue.2, pp.61-493, 2009.
DOI : 10.1002/mrm.21834

K. Setsompop, V. Alagappan, A. C. Zelinski, A. Potthast, U. Fontius et al., High-flip-angle slice-selective parallel RF transmission with 8 channels at 7T, Journal of Magnetic Resonance, vol.195, issue.1, pp.76-84, 2008.
DOI : 10.1016/j.jmr.2008.08.012

K. Setsompop, L. L. Wald, V. Alagappan, B. Gagoski, F. Hebrank et al., Parallel RF transmission with eight channels at 3 Tesla, Magnetic Resonance in Medicine, vol.33, issue.5, pp.1163-1171, 2006.
DOI : 10.1002/mrm.21042

K. Setsompop, L. L. Wald, V. Alagappan, B. A. Gagoski, and E. Adalsteinsson, Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels, Magnetic Resonance in Medicine, vol.74, issue.4, pp.908-915, 2008.
DOI : 10.1002/mrm.21513

L. Silbert, J. Quinn, M. Moore, E. Corbridge, M. Ball et al., Changes in premorbid brain volume predict Alzheimer's disease pathology, Neurology, vol.61, issue.4, pp.487-492, 2003.
DOI : 10.1212/01.WNL.0000079053.77227.14

M. Silver, R. Joseph, and D. Hoult, Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equation, Physical Review A, vol.31, issue.4, pp.2753-2755, 1985.
DOI : 10.1103/PhysRevA.31.2753

S. M. Smith, Fast robust automated brain extraction, Human Brain Mapping, vol.20, issue.3, pp.143-155, 2002.
DOI : 10.1002/hbm.10062

D. K. Sodickson and W. J. Manning, Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays, Magnetic Resonance in Medicine, vol.18, issue.4, pp.591-603, 1997.
DOI : 10.1002/mrm.1910380414

R. S. Staewen, A. J. Johnson, B. D. Ross, T. Parrish, H. Merkle et al., 3-D FLASH Imaging Using a Single Surface Coil and a New Adiabatic Pulse, BIR-4, INVESTIGATIVE RADIOLOGY, vol.25, issue.5, pp.559-567, 1990.
DOI : 10.1097/00004424-199005000-00015

R. Stollberger and P. Wach, Imaging of the activeB1 fieldin vivo, Magnetic Resonance in Medicine, vol.8, issue.2, pp.246-251, 1996.
DOI : 10.1002/mrm.1910350217

F. Strumwasser, Long-Term Recording from Single Neurons in Brain of Unrestrained Mammals, Science, vol.127, issue.3296, pp.469-470, 1958.
DOI : 10.1126/science.127.3296.469

M. Styner, C. Brechbühler, G. Székely, and G. Gerig, Parametric estimate of intensity inhomogeneities applied to MRI, IEEE Transactions on Medical Imaging, vol.19, issue.3, pp.153-165, 2000.
DOI : 10.1109/42.845174

M. J. Thieben, A. J. Duggins, C. D. Good, L. Gomes, N. Mahant et al., The distribution of structural neuropathology in pre-clinical Huntington's disease, Brain, vol.125, issue.8, pp.1815-1828, 2002.
DOI : 10.1093/brain/awf179

C. Triantafyllou, R. D. Hoge, G. Krueger, C. J. Wiggins, A. Potthast et al., Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters, NeuroImage, vol.26, issue.1, pp.243-250, 2005.
DOI : 10.1016/j.neuroimage.2005.01.007

P. Ullmann, S. Junge, M. Wick, F. Seifert, W. Ruhm et al., Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels, Magnetic Resonance in Medicine, vol.6, issue.4, pp.994-1001, 2005.
DOI : 10.1002/mrm.20646

K. Vahedipour, T. Stocker, D. Brenner, and N. Shah, Parallel excitation of a 3D ROI inside a post mortem brain, Proc. Intl. Soc. Mag. Reson. Med. Stockholm, p.4917, 2010.

P. Van-de-moortele, C. Akgun, G. Adriany, S. Moeller, J. Ritter et al., B(1) destructive interferences and spatial phase patterns at 7 T with ah e a dt r a n s c e i v e ra r r a yc o i l, 2005.

P. Van-de-moortele, E. J. Auerbach, C. Olman, E. Yacoub, K. Ugurbil et al., T1 weighted brain images at 7??Tesla unbiased for Proton Density, T2??? contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization, NeuroImage, vol.46, issue.2, pp.432-446, 2009.
DOI : 10.1016/j.neuroimage.2009.02.009

P. Van-de-moortele, C. Snyder, L. Delabarre, A. Gregor, T. Vaughan et al., Calibration Tools for RF Shim at Very High Field with Multiple Element RF Coils: From Ultra Fast Local Relative Phase to Absolute Magnitude B1+ Mapping, Proc. Inl. Soc. Mag. Reson. Med. Berlin, p.1676, 2007.

A. Van-der-kouwe, T. Benner, and D. Salat, Brain morphometry with multiecho MPRAGE, NeuroImage, vol.40, issue.2, pp.559-569, 2008.
DOI : 10.1016/j.neuroimage.2007.12.025

J. T. Vaughan, H. Hetherington, J. Otu, J. Pan, and G. Pohost, High frequency volume coils for clinical NMR imaging and spectroscopy, Magnetic Resonance in Medicine, vol.3, issue.2, pp.206-218, 1994.
DOI : 10.1002/mrm.1910320209

M. Vogel and R. Kleihorst, Large-Scale Simulations Including a Human-Body Model for MRI, 2007 IEEE/MTT-S International Microwave Symposium, pp.1345-1348, 2007.
DOI : 10.1109/MWSYM.2007.380461

T. Voigt, O. Doessel, and U. Katscher, Imaging conductivity and local SAR of the human brain, Proc. Intl. Soc. Mag. Reson. Med. Honolulu, p.4513, 2009.

V. Economo, C. Koskinas, and G. , Die Cytoarchitektonik der Hirnrinde des erwachsenen Menschen, 1927.

L. L. Wald, L. Carvajal, S. E. Moyher, S. J. Nelson, P. E. Grant et al., Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain, Magnetic Resonance in Medicine, vol.28, issue.3, pp.433-439, 1995.
DOI : 10.1002/mrm.1910340321

J. Wang, M. Qiu, Q. X. Yang, M. B. Smith, and R. T. Constable, Measurement and correction of transmitter and receiver induced nonuniformities in vivo, Magnetic Resonance in Medicine, vol.9, issue.2, pp.408-417, 2005.
DOI : 10.1002/mrm.20354

R. Wangsness and F. Bloch, The Dynamical Theory of Nuclear Induction, Physical Review, vol.89, issue.4, pp.728-739, 1953.
DOI : 10.1103/PhysRev.89.728

M. Weiger, K. P. Pruessmann, R. Österbauer, P. Bornert, P. Bo-esiger et al., Sensitivity-encoded single-shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI, Magnetic Resonance in Medicine, vol.46, issue.5, pp.860-866, 2002.
DOI : 10.1002/mrm.10286

C. J. Wiggins, M. Caillat, D. L. Bihan, F. Schmitt, and E. Eberlein, Use of Opposed Shim Currents for Infold Reduction on a UHF MRI System with Head Gradient, Proc. Inl. Soc. Mag. Reson. Med. Stockholm, p.2339, 2010.

G. C. Wiggins, C. Triantafyllou, A. Potthast, A. Reykowski, M. Nittka et al., 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry, Magnetic Resonance in Medicine, vol.47, issue.1, pp.216-223, 2006.
DOI : 10.1002/mrm.20925

D. Xu, K. King, Y. Zhu, G. C. Mckinnon, and Z. Liang, Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approach, Magnetic Resonance in Medicine, vol.46, issue.3, pp.547-560, 2008.
DOI : 10.1002/mrm.21485

D. Xu, K. F. King, Y. Zhu, G. C. Mckinnon, and Z. Liang, A noniterative method to design large-tip-angle multidimensional spatially-selective radio frequency pulses for parallel transmission, Magnetic Resonance in Medicine, vol.51, issue.2, pp.326-334, 2007.
DOI : 10.1002/mrm.21314

E. Yacoub, N. Harel, and K. Ugurbil, High-field fMRI unveils orientation columns in humans, Pro c. Natl. Acad. Sci. USA. 105, pp.10607-10612, 2008.
DOI : 10.1073/pnas.0804110105

Q. X. Yang, W. Mao, J. Wang, M. B. Smith, H. Lei et al., Manipulation of image intensity distribution at 7.0 T: Passive RF shimming and focusing with dielectric materials, Journal of Magnetic Resonance Imaging, vol.42, issue.1, pp.197-202, 2006.
DOI : 10.1002/jmri.20603

Q. X. Yang, J. Wang, C. M. Collins, M. B. Smith, X. Zhang et al., Phantom design method for high-field MRI human systems, Magnetic Resonance in Medicine, vol.32, issue.5, pp.1016-1020, 2004.
DOI : 10.1002/mrm.20245

Q. X. Yang, J. Wang, X. Zhang, C. M. Collins, M. B. Smith et al., Analysis of wave behavior in lossy dielectric samples at high field, Magnetic Resonance in Medicine, vol.32, issue.5, pp.47-982, 2002.
DOI : 10.1002/mrm.10137

V. L. Yarnykh, Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field, Magnetic Resonance in Medicine, vol.55, issue.1, pp.192-200, 2007.
DOI : 10.1002/mrm.21120

C. Yip, J. A. Fessler, and D. C. Noll, Iterative RF pulse design for multidimensional, small-tip-angle selective excitation, Magnetic Resonance in Medicine, vol.37, issue.4, pp.908-917, 2005.
DOI : 10.1002/mrm.20631

C. Yip, J. A. Fessler, and D. C. Noll, Advanced three-dimensional tailored RF pulse for signal recovery inT2*-weighted functional magnetic resonance imaging, Magnetic Resonance in Medicine, vol.48, issue.5, pp.1050-1059, 2006.
DOI : 10.1002/mrm.21048

M. G. Zanchi, P. Stang, A. Kerr, J. M. Pauly, and G. C. Scott, Frequency-Offset Cartesian Feedback for MRI Power Amplifier Linearization, IEEE Transactions on Medical Imaging, vol.30, issue.2, pp.512-522, 2011.
DOI : 10.1109/TMI.2010.2087768

A. Zelinski, V. Alagappan, V. Goyal, E. Adalsteinsson, and L. Wald, Sparsity-Enforced Coil Array Mode Compression for Parallel Transmission, Proc. Intl. Soc. Mag. Reson. Med. Toronto, p.1302, 2008.

A. Zelinski, V. K. Goyal, L. Angelone, G. Bonmassar, L. Wald et al., Designing RF Pulses with Optimal Specific Absorption Rate (SAR) Characteristics and Exploring Excitation Fidelity, SAR and Pulse Duration Tradeoffs, Proc. Intl. Soc. Mag. Reson. Med. Berlin, p.1699, 2007.

A. C. Zelinski, L. M. Angelone, V. K. Goyal, G. Bonmassar, E. Adalsteinsson et al., Specific absorption rate studies of the parallel transmission of inner-volume excitations at 7T, Journal of Magnetic Resonance Imaging, vol.57, issue.4, pp.1005-1018, 2008.
DOI : 10.1002/jmri.21548

A. C. Zelinski, L. L. Wald, K. Setsompop, V. Alagappan, B. A. Gagoski et al., Fast slice-selective radio-frequency excitation pulses for mitigatingB+1 inhomogeneity in the human brain at 7 Tesla, Magnetic Resonance in Medicine, vol.2, issue.6, pp.1355-1364, 2008.
DOI : 10.1002/mrm.21585

A. C. Zelinski, L. L. Wald, K. Setsompop, V. K. Goyal, and E. Adalsteinsson, Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design, IEEE Transactions on Medical Imaging, vol.27, issue.9, pp.1213-1229, 2008.
DOI : 10.1109/TMI.2008.920605

Y. Zhu, Parallel excitation with an array of transmit coils, Magnetic Resonance in Medicine, vol.38, issue.4, pp.775-784, 2004.
DOI : 10.1002/mrm.20011