<?xml version="1.0" encoding="utf-8"?>
<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of tel-01403314</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-23T03:38:28+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">Balancing circuit control of energy storage system (supercapacitors) for state of health estimation and lifetime maximization</title>
            <title xml:lang="fr">Contrôle des circuits d’équilibrage des systèmes de stockage d’énergie (supercondensateurs) en vue d’estimer et d’améliorer leur durée de vie</title>
            <author role="aut">
              <persName>
                <forename type="first">Seïma</forename>
                <surname>Shili</surname>
              </persName>
              <idno type="halauthorid">1040862-0</idno>
              <affiliation ref="#struct-31070"/>
              <affiliation ref="#struct-408749"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>ABES</forename>
                <surname>STAR</surname>
              </persName>
              <email type="md5">f5aa7f563b02bb6adbba7496989af39a</email>
              <email type="domain">abes.fr</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2016-11-25 16:56:25</date>
              <date type="whenModified">2026-05-23 03:37:29</date>
              <date type="whenReleased">2016-11-29 10:00:18</date>
              <date type="whenProduced">2016-07-11</date>
              <date type="whenEndEmbargoed">2016-11-25</date>
              <ref type="file" target="https://theses.hal.science/tel-01403314v1/document">
                <date notBefore="2016-11-25"/>
              </ref>
              <ref type="file" subtype="author" n="1" target="https://theses.hal.science/tel-01403314v1/file/TH2016SHILISEIMA.pdf" id="file-1403314-1489633">
                <date notBefore="2016-11-25"/>
              </ref>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="131274">
                <persName>
                  <forename>ABES</forename>
                  <surname>STAR</surname>
                </persName>
                <email type="md5">f5aa7f563b02bb6adbba7496989af39a</email>
                <email type="domain">abes.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">tel-01403314</idno>
            <idno type="halUri">https://theses.hal.science/tel-01403314</idno>
            <idno type="halBibtex">shili:tel-01403314</idno>
            <idno type="halRefHtml">Energie électrique. Université de Lyon, 2016. Français. &lt;a target="_blank" href="https://www.theses.fr/2016LYSE1124"&gt;&amp;#x27E8;NNT : 2016LYSE1124&amp;#x27E9;&lt;/a&gt;</idno>
            <idno type="halRef">Energie électrique. Université de Lyon, 2016. Français. &amp;#x27E8;NNT : 2016LYSE1124&amp;#x27E9;</idno>
            <availability status="restricted">
              <licence target="https://about.hal.science/hal-authorisation-v1/">HAL Authorization<ref corresp="#file-1403314-1489633"/></licence>
            </availability>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="CNRS">CNRS - Centre national de la recherche scientifique</idno>
            <idno type="stamp" n="UNIV-LYON1">Université Claude Bernard - Lyon I</idno>
            <idno type="stamp" n="INSA-LYON">Institut National des Sciences Appliquées de Lyon</idno>
            <idno type="stamp" n="EC-LYON">Ecole Centrale de Lyon</idno>
            <idno type="stamp" n="AMPERE" corresp="UNIV-LYON1">Ampère</idno>
            <idno type="stamp" n="AMPERE-THESE">Thèses du laboratoire Ampère</idno>
            <idno type="stamp" n="STAR">STAR - Dépôt national des thèses électroniques</idno>
            <idno type="stamp" n="THESES_LYON1" corresp="UNIV-LYON1">Thèses Université Claude Bernard Lyon 1</idno>
            <idno type="stamp" n="INSA-LYON-THESES" corresp="INSA-LYON">Thèses de l'INSA Lyon</idno>
            <idno type="stamp" n="INSA-GROUPE">Groupe INSA</idno>
            <idno type="stamp" n="AMP-F13">AMPERE-F13</idno>
            <idno type="stamp" n="AMP-F17">AMPERE-F17</idno>
            <idno type="stamp" n="AMP-F20">AMPERE-F20</idno>
            <idno type="stamp" n="UDL">UDL</idno>
            <idno type="stamp" n="UNIV-LYON">Université de Lyon</idno>
            <idno type="stamp" n="INRAE">Institut National de Recherche en Agriculture, Alimentation et Environnement</idno>
          </seriesStmt>
          <notesStmt/>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">Balancing circuit control of energy storage system (supercapacitors) for state of health estimation and lifetime maximization</title>
                <title xml:lang="fr">Contrôle des circuits d’équilibrage des systèmes de stockage d’énergie (supercondensateurs) en vue d’estimer et d’améliorer leur durée de vie</title>
                <author role="aut">
                  <persName>
                    <forename type="first">Seïma</forename>
                    <surname>Shili</surname>
                  </persName>
                  <idno type="halauthorid">1040862-0</idno>
                  <affiliation ref="#struct-31070"/>
                  <affiliation ref="#struct-408749"/>
                </author>
              </analytic>
              <monogr>
                <idno type="nnt">2016LYSE1124</idno>
                <imprint>
                  <date type="dateDefended">2016-07-11</date>
                </imprint>
                <authority type="institution">Université de Lyon</authority>
                <authority type="school">École doctorale Électronique, électrotechnique, automatique (Lyon)</authority>
                <authority type="supervisor">Pascal Venet</authority>
                <authority type="supervisor">Alaa Hijazi</authority>
                <authority type="supervisor">Ali Sari</authority>
                <authority type="jury">Christophe Forgez [Président]</authority>
                <authority type="jury">Amine Lahyani [Rapporteur]</authority>
                <authority type="jury">Jean-Michel Vinassa [Rapporteur]</authority>
                <authority type="jury">Jean-Christophe Crebier</authority>
                <authority type="jury">Serge Pélissier</authority>
              </monogr>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="fr">French</language>
            </langUsage>
            <textClass>
              <keywords scheme="author">
                <term xml:lang="en">Equivalent series resistance</term>
                <term xml:lang="en">Energy storage system</term>
                <term xml:lang="en">State of Halth</term>
                <term xml:lang="en">Lifetime</term>
                <term xml:lang="en">Balancing circuit</term>
                <term xml:lang="en">Supercapacitor</term>
                <term xml:lang="fr">Système de gestion d’énergie</term>
                <term xml:lang="fr">Résistance équivalente série</term>
                <term xml:lang="fr">Etat de Santé</term>
                <term xml:lang="fr">Durée de vie</term>
                <term xml:lang="fr">Circuit d’équilibrage</term>
                <term xml:lang="fr">Supercondensateur</term>
              </keywords>
              <classCode scheme="halDomain" n="spi.nrj">Engineering Sciences [physics]/Electric power</classCode>
              <classCode scheme="halTypology" n="THESE">Theses</classCode>
              <classCode scheme="halOldTypology" n="THESE">Theses</classCode>
              <classCode scheme="halTreeTypology" n="THESE">Theses</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>Energy storage system such as supercapacitors are widely used in high power applications. However, due to single cell voltage limitation, an energy storage system (module) is often employed. It contains a chain structure of identical elements and ensures voltage adaptation to the corresponding application requirements. Energy management systems are associated to energy storage systems in order to assure user and equipment security. Their main role is to monitor and control energy storage systems elements continuously. The work presented aims to enhance the lifetime of energy storage systems. It relies on establishing balancing circuits on the terminals of the storage system elements. These control circuits are energy management system devices. Thus, various control approaches are discussed, analyzed and compared. They aim to estimate the supercapacitor's state of health. In addition, a new approach of balancing circuits is proposed. It is based on estimating the level of degradation of the elements. Thus, It allows aging speed equalization between module elements and storage system lifetime maximization. Some main results of the work could be generalized to batteries</p>
            </abstract>
            <abstract xml:lang="fr">
              <p>Dans les applications de puissance, les systèmes de stockage d'énergie électrique tels que les supercondensateurs sont fortement sollicités. Compte tenu des limitations existantes lors de l'utilisation d'un seul composant, un système de stockage d'énergie électrique (module) est constitué d'une association d'éléments (cellules) permettant de s'adapter aux besoins de l'application visée. Afin d'assurer la sécurité de l'équipement et de son utilisateur, un système de gestion d'énergie, qui a pour rôle de surveiller et de contrôler continuellement les cellules, est associé au module de stockage. Le but des travaux de thèse est l'amélioration de la durée de vie des systèmes de stockage d'énergie. Cet objectif est réalisé grâce au contrôle des circuits d'équilibrage, éléments du système de gestion d'énergie, et déjà présents sur ces modules de stockage. Différentes méthodes de contrôle sont donc présentées, analysées et comparées afin d'évaluer l'état de santé des supercondensateurs surveillés. Une nouvelle approche d'équilibrage se basant sur le niveau de dégradation estimée est exposée. Elle permet d'équilibrer les vitesses de vieillissement des cellules et ainsi de prolonger la durée de vie de l'ensemble du système. Certains principes des résultats obtenus sont transposables aux batteries</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-31070" status="OLD">
          <idno type="IdRef">149693435</idno>
          <idno type="ISNI">0000000123052936</idno>
          <idno type="RNSR">199911701C</idno>
          <idno type="ROR">https://ror.org/04xbczw40</idno>
          <idno type="Wikidata">Q2374376</idno>
          <orgName>Ampère</orgName>
          <orgName type="acronym">AMPERE</orgName>
          <date type="start">2007-01-01</date>
          <date type="end">2025-12-31</date>
          <desc>
            <address>
              <addrLine>Ecole Centrale de Lyon, 36 Avenue Guy de Collongue, 69134 Ecully CEDEX</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.ampere-lab.fr/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-126765" type="direct"/>
            <relation active="#struct-301088" type="indirect"/>
            <relation active="#struct-194495" type="direct"/>
            <relation active="#struct-219748" type="direct"/>
            <relation active="#struct-301232" type="indirect"/>
            <relation name="UMR5005" active="#struct-441569" type="direct"/>
            <relation name="USC1407" active="#struct-577435" type="direct"/>
          </listRelation>
        </org>
        <org type="department" xml:id="struct-408749" status="OLD">
          <orgName>Ampère, Département Méthodes pour l'Ingénierie des Systèmes</orgName>
          <orgName type="acronym">MIS</orgName>
          <date type="start">2011-01-01</date>
          <date type="end">2020-12-31</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.ampere-lab.fr/spip.php?rubrique90</ref>
          </desc>
          <listRelation>
            <relation active="#struct-31070" type="direct"/>
            <relation active="#struct-126765" type="indirect"/>
            <relation active="#struct-301088" type="indirect"/>
            <relation active="#struct-194495" type="indirect"/>
            <relation active="#struct-219748" type="indirect"/>
            <relation active="#struct-301232" type="indirect"/>
            <relation name="UMR5005" active="#struct-441569" type="indirect"/>
            <relation name="USC1407" active="#struct-577435" type="indirect"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-126765" status="VALID">
          <idno type="ROR">https://ror.org/05s6rge65</idno>
          <orgName>École Centrale de Lyon</orgName>
          <orgName type="acronym">ECL</orgName>
          <desc>
            <address>
              <addrLine>36 avenue Guy de Collongue - 69134 Ecully cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.ec-lyon.fr</ref>
          </desc>
          <listRelation>
            <relation active="#struct-301088" type="direct"/>
          </listRelation>
        </org>
        <org type="regroupinstitution" xml:id="struct-301088" status="VALID">
          <idno type="ROR">https://ror.org/01rk35k63</idno>
          <orgName>Université de Lyon</orgName>
          <desc>
            <address>
              <addrLine>92 rue Pasteur - CS 30122, 69361 Lyon Cedex 07</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.universite-lyon.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-194495" status="VALID">
          <idno type="IdRef">026402823</idno>
          <idno type="ISNI">0000000121686185</idno>
          <idno type="ROR">https://ror.org/029brtt94</idno>
          <orgName>Université Claude Bernard Lyon 1</orgName>
          <orgName type="acronym">UCBL</orgName>
          <desc>
            <address>
              <addrLine>43, boulevard du 11 novembre 1918, 69622 Villeurbanne cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.univ-lyon1.fr/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-301088" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-219748" status="VALID">
          <idno type="IdRef">052444724</idno>
          <idno type="ISNI">0000 0001 2292 0228</idno>
          <orgName>Institut National des Sciences Appliquées de Lyon</orgName>
          <orgName type="acronym">INSA Lyon</orgName>
          <date type="start">1957-03-18</date>
          <desc>
            <address>
              <addrLine>20 Avenue Albert Einstein, 69621 Villeurbanne cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.insa-lyon.fr/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-301088" type="direct"/>
            <relation active="#struct-301232" type="direct"/>
          </listRelation>
        </org>
        <org type="regroupinstitution" xml:id="struct-301232" status="VALID">
          <idno type="IdRef">162105150</idno>
          <orgName>Institut National des Sciences Appliquées</orgName>
          <orgName type="acronym">INSA</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
        <org type="regroupinstitution" xml:id="struct-441569" status="VALID">
          <idno type="IdRef">02636817X</idno>
          <idno type="ISNI">0000000122597504</idno>
          <idno type="ROR">https://ror.org/02feahw73</idno>
          <orgName>Centre National de la Recherche Scientifique</orgName>
          <orgName type="acronym">CNRS</orgName>
          <date type="start">1939-10-19</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.cnrs.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-577435" status="VALID">
          <idno type="ROR">https://ror.org/003vg9w96</idno>
          <orgName>Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement</orgName>
          <orgName type="acronym">INRAE</orgName>
          <date type="start">2020-01-01</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>